Top 10 similar words or synonyms for mach_zehnder

interferometers    0.769084

mach_zehnder_interferometer    0.768548

beam_splitters    0.746696

michelson_interferometer    0.742999

fabry_pérot    0.730409

interferometric    0.730301

spectrometers    0.727191

wavefront_sensor    0.722831

photoelastic    0.717922

millimetre_wave    0.716790

Top 30 analogous words or synonyms for mach_zehnder

Article Example
MachZehnder interferometer MachZehnder interferometers are used in electro-optic modulators, electronic devices used in various fibre-optic communications applications. Mach-Zehnder modulators are incorporated in monolithic integrated circuits and offer well-behaved, high-bandwidth electro-optic amplitude and phase responses over a multiple GHz frequency range.
MachZehnder interferometer At detector 2, in the absence of a sample, the sample beam and reference beam will arrive with a phase difference of half a wavelength, yielding complete destructive interference. The RB arriving at detector 2 will have undergone a phase shift of (0.5×wavelength + 2"k") due to one front-surface reflection and two transmissions. The SB arriving at detector 2 will have undergone a (1×wavelength + 2"k") phase shift due to two front-surface reflections and one rear-surface reflection. Therefore, when there is no sample, only detector 1 receives light.
MachZehnder interferometer Collimated sources result in a nonlocalized fringe pattern. Localized fringes result when an extended source is used. In Fig. 2, we see that the fringes can be adjusted so that they are localized in any desired plane. In most cases, the fringes would be adjusted to lie in the same plane as the test object, so that fringes and test object can be photographed together.
MachZehnder interferometer The Fresnel equations for reflection and transmission of a wave at a dielectric imply that there is a phase change for a reflection when a wave reflects off a change from low to high refractive index but not when it reflects off a change from high to low.
MachZehnder interferometer Caveat: The rule about phase shifts applies to beamsplitters constructed with a dielectric coating, and must be modified if a metallic coating is used, or when different polarizations are taken into account. Also, in real interferometers, the thicknesses of the beamsplitters may differ, and the path lengths are not necessarily equal. Regardless, in the absence of absorption, conservation of energy guarantees that the two paths must differ by a half wavelength phase shift. Also note that beamsplitters that are not 50/50 are frequently employed to improve the interferometer's performance in certain types of measurement.